Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Biochem ; 656: 114880, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36063916

RESUMO

MicroRNAs (miRNAs) are potential clinical biomarkers for the detection of various diseases. However, their quantification has not been implemented in clinical practice given the inconsistencies in their variable recovery rate and accuracy of the results. Thus, we utilized a technique based on bioluminescent enzyme immunoassay (BLEIA) to perform fully automated miRNA quantification using magnetic particles conjugated with antibodies targeting DNA-RNA hybrids, biotinylated DNA probes specific to miRNAs, and firefly luciferase-labeled streptavidin. This method enabled direct use of diluted serum and automation of all processes within 1 hr. The results revealed a wide linear range between 10 fmol/L and 1 nmol/L, high sensitivity with a detection limit of 6.3 fmol/L or below, high specificity with a false positive rate under 2.4%, and high reproducibility in intra- and inter-experimental observations (under CV 10% and r = 0.9965, respectively). Furthermore, a significant correlation was revealed between quantitative reverse transcription-polymerase chain reaction and BLEIA assay for the quantification of synthetic miRNA (r = 0.9993) and endogenous miRNA in healthy serums (r = 0.8203), respectively. Overall, we developed a fully automated miRNA quantification method based on BLEIA, which can be adopted in a clinical setting. However, further studies are needed to assess its clinical performance.


Assuntos
MicroRNAs , Biomarcadores , DNA , Sondas de DNA , Imunoensaio/métodos , Técnicas Imunoenzimáticas , Luciferases de Vaga-Lume , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estreptavidina
2.
Biosci Biotechnol Biochem ; 85(2): 359-368, 2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33604636

RESUMO

Personalized peptide vaccination, which involves activation of the host immune system against cancer cells using personalized peptide vaccines (PPVs), can improve overall survival in multiple cancer types. However, the clinical efficacies of PPVs vary for unknown reasons. Recently, a single nucleotide polymorphism (NG_012651.1:g.4461_5460[4960A>G]) in the haptoglobin promoter region, rs5472, was significantly associated with clinical response of PPV. Therefore, rs5472 is expected to be a predictive biomarker for PPV therapy. Here, we described a single nucleotide discrimination method for rs5472 analysis by combining the loop-mediated isothermal amplification and quenching probe methods. In evaluation of saliva samples, this method showed high concordance with the results of Sanger sequencing (100%, n = 36). Importantly, this method did not require calculation of melting temperature for single nucleotide discrimination and could therefore be carried out on a simple instrument. Accordingly, this method may be more robust and applicable to near-patient testing.


Assuntos
Corantes Fluorescentes/metabolismo , Haptoglobinas/genética , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Polimorfismo de Nucleotídeo Único , Regiões Promotoras Genéticas/genética , Humanos , Saliva/metabolismo
3.
J Microbiol ; 53(1): 1-5, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25557475

RESUMO

Loop-mediated isothermal amplification (LAMP), a newly developed gene amplification method, combines rapidity, simplicity, and high specificity. Several tests have been developed based on this method, and simplicity is maintained throughout all steps, from extraction of nucleic acids to detection of amplification. In the LAMP reaction, samples are amplified at a fixed temperature through a repetition of two types of elongation reactions occurring at the loop regions: self-elongation of templates from the stem loop structure formed at the 3'-terminal and the binding and elongation of new primers to the loop region. The LAMP reaction has a wide range of possible applications, including point-of-care testing, genetic testing in resource-poor settings (such as in developing countries), and rapid testing of food products and environmental samples.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Primers do DNA , Testes Genéticos , Humanos , Sequências Repetidas Invertidas , Orthomyxoviridae/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Temperatura , Tuberculose/diagnóstico
4.
J Infect Dis ; 208(4): 637-44, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23633403

RESUMO

BACKGROUND: Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. METHODS: The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum-specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. RESULTS: A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. CONCLUSIONS: Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy.


Assuntos
Malária Falciparum/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Parasitologia/métodos , Plasmodium falciparum/isolamento & purificação , Medicina de Viagem/métodos , Adulto , Sangue/parasitologia , Feminino , Humanos , Masculino , Microscopia , Plasmodium falciparum/genética , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
5.
Nat Protoc ; 3(5): 877-82, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18451795

RESUMO

As the human genome is decoded and its involvement in diseases is being revealed through postgenome research, increased adoption of genetic testing is expected. Critical to such testing methods is the ease of implementation and comprehensible presentation of amplification results. Loop-mediated isothermal amplification (LAMP) is a simple, rapid, specific and cost-effective nucleic acid amplification method when compared to PCR, nucleic acid sequence-based amplification, self-sustained sequence replication and strand displacement amplification. This protocol details an improved simple visual detection system for the results of the LAMP reaction. In LAMP, a large amount of DNA is synthesized, yielding a large pyrophosphate ion by-product. Pyrophosphate ion combines with divalent metallic ion to form an insoluble salt. Adding manganous ion and calcein, a fluorescent metal indicator, to the reaction solution allows a visualization of substantial alteration of the fluorescence during the one-step amplification reaction, which takes 30-60 min. As the signal recognition is highly sensitive, this system enables visual discrimination of results without costly specialized equipment. This detection method should be helpful in basic research on medicine and pharmacy, environmental hygiene, point-of-care testing and more.


Assuntos
DNA/química , Genômica/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Primers do DNA/genética , Difosfatos/química , Fluoresceínas , Humanos , Manganês , Metais/química
6.
Anal Chem ; 76(13): 3689-93, 2004 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15228342

RESUMO

We have successfully achieved the integration of isothermal amplification and the subsequent analysis of specific gene fragments on poly(methyl methacrylate) microchips. In our experiments, loop-mediated isothermal amplification, which can offer higher specificity and efficiency than PCR, has been performed at a constant temperature (65 degrees C). After amplification, products could be either examined by the integrated microchip-based electrophoresis or directly observed by naked eye with SYBR Green I added into the reaction solution. By such an integrated microsystem, the amplification and the subsequent analysis of prostate-specific antigen gene with template concentration at 23 fg/microL could be finished within 15 min, which demonstrates its advantages of high specificity, good reproducibility, and fast speed in gene detection.


Assuntos
DNA/análise , Eletroforese em Microchip/métodos , Genes/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Polimetil Metacrilato/química , Antígeno Prostático Específico/genética , DNA/genética , Eletroforese em Microchip/instrumentação , Sensibilidade e Especificidade , Propriedades de Superfície , Temperatura
7.
J Biochem Biophys Methods ; 59(2): 145-57, 2004 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-15163526

RESUMO

Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification method that allows the synthesis of large amounts of DNA in a short period of time with high specificity. As the LAMP reaction progresses, the reaction by-product pyrophosphate ions bind to magnesium ions and form a white precipitate of magnesium pyrophosphate. We designed an apparatus capable of measuring the turbidity of multiple samples simultaneously while maintaining constant temperature to conduct real-time measurements of the changes in the turbidity of LAMP reactions. The time (Tt) required for the turbidity of the LAMP reaction solution to exceed a given value was dependent on the quantity of the initial template DNA. That is, a graph with the plot of Tt versus the log of the amount of initial template DNA was linear from 2 x 10(3) copies (0.01 pg/tube) to 2 x 10(9) copies (100 ng/tube) of template DNA. These results indicate that real-time turbidity measurements of the LAMP reaction permit the quantitative analysis of minute amounts of nucleic acids present in a sample, with a high precision over a wide range, using a simple apparatus reported in this study.


Assuntos
DNA/análise , Nefelometria e Turbidimetria/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Moldes Genéticos , Sequência de Bases , DNA/genética , Eletroforese em Gel de Ágar , Nefelometria e Turbidimetria/instrumentação , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...